Buffalo grounding and bonding, the half nobody sees

Grounding does nothing at all until the day something goes wrong, and then it does everything. That is exactly why it gets neglected: an installation with no working earth path behaves normally for years.

  • earth path traced rather than assumed
  • findings shown, not asserted
  • corrections documented for your records

What it does

Grounding and bonding gives a fault somewhere to go

When a live conductor touches something it should not, the ground path gives that current a route back that trips the protection instead of routing it through whoever is holding the appliance.

Bonding is the related idea: metal parts that could become live are tied together so they cannot sit at different voltages. Water pipes, gas lines and structural metal are the usual candidates, and the connections are unglamorous and easy to leave out. A panel inspection is where most of them get checked.

None of this shows up in daily use, which is why it is a standing item in an electrical safety inspection rather than something people call about. It is also why a pre purchase inspection includes it: an ungrounded installation looks completely normal to a buyer.

Fresh install
Breakers assembled on a DIN rail before installation, for grounding and bonding in Buffalo
Running cable overhead in a commercial building, for grounding and bonding in Buffalo

How it runs

A grounding and bonding check in Buffalo, four steps

  1. Start at the service

    Where the ground starts and how it is connected. Everything downstream depends on this being right.

  2. Test continuity, do not assume

    A conductor that is present is not the same as a path that works. Testing is the only way to know.

  3. Check the separations

    Neutrals and grounds must be joined at the main and separated in any subpanel. It is a frequent and consequential mistake.

  4. Correct and document

    Put right, then written up, because this is the sort of finding an insurer or a buyer will ask about.

What we find

Three grounding and bonding faults we see repeatedly

A path that was never continuous is the most common: a ground conductor connected at one end and not the other, or interrupted where a circuit was extended years later. Continuity testing finds it in minutes and nothing else does.

Neutrals and grounds bonded together in a subpanel is the second. They must be separated there and joined only at the main, and getting it wrong is one of the most frequent findings in work done without inspection. Subpanel installation sets out why the arrangement differs from the main panel.

Where any of these turn up, correcting them is straightforward and it is documented, which matters if the work formed part of a code correction or is going to be shown to an insurer alongside a certificate of inspection.

An electrician working in an outdoor service cabinet, for grounding and bonding in Buffalo
An interrupted path Most common
Neutrals bonded in a subpanel Second
Bonding jumper removed Third

Related work

Where Buffalo grounding comes up

All install services

Common questions

Buffalo grounding questions

You would not, and that is the problem. An installation with no working earth path behaves completely normally until the day something faults. Only testing finds it.
Because they are joined once, at the main. Joining them again downstream puts current on the ground path in normal use, which is exactly what it is not for.
It can. The bonding jumper often goes out with the old metal pipe, and the protection that depended on it disappears without anyone noticing.
No. A three-prong outlet can be fitted to a two-wire circuit with nothing behind the third pin. Testing tells you; the outlet face does not.
Usually far less than people expect, because it is often one connection rather than rewiring. We tell you which before quoting.
It protects people, which is the important part, and it is the accepted answer where no ground exists. It does not protect equipment, and the outlet has to be labelled so the next person knows.

Customer reviews

What Buffalo customers say about the grounding

★★★★★ 4.9 · 127 reviews on Google
Read all reviews →
★★★★★

Found a ground conductor connected at one end only. Twenty years like that.

M. Sørensen
Grounding check, Buffalo
★★★★★

Neutrals and grounds bonded in the subpanel. Explained clearly why that mattered.

R. Oyelowo
Subpanel fault, Amherst
★★★★★

Spotted the missing bonding jumper. Our plumber had no idea it was needed.

K. Vasquez
After replumbing, Tonawanda
★★★★★

Tested rather than trusting the outlet faces. Half of them had nothing behind them.

T. Brennan
Three-prong outlets, West Seneca

From the blog

Buffalo safety guides

All Electrical Guides
Electrical panel assessed during a service upgrade quote in Buffalo Panels & Service Upgrades

August 19, 2026 8 min read

Do I Need an Electrical Panel Upgrade in Buffalo, or Just More Room?

A full panel and an undersized service are different problems with very different prices. What a load calculation actually measures, when a subpanel is the honest answer, and what a service upgrade costs once the permit and the utility work are counted.

Read article

Next step

Get grounding and bonding checked in Buffalo

Tested rather than assumed, shown rather than asserted, and documented if anything needs correcting.

Continuity tested · Findings shown · Corrections documented