Most flicker is a dimmer and a driver that were never designed to work together, and it costs almost nothing to put right. A small proportion is a connection failing, and that one does not improve on its own.
The harmless kind
Modern lamps contain a driver, and not every driver works with every dimmer. The symptom is flicker or a faint buzz at the lower end of the range, steady at full output, and identical every time. It is a compatibility problem rather than a fault, and it is a different thing entirely from light fixture repair.
The fix is matching the two, which usually means the right dimmer rather than different lamps. Anyone selling you a rewire for this is answering the wrong question. Where the fitting is being changed anyway, light fixture installation covers picking the pairing before ordering rather than afterwards.
The same applies to downlights, which are the most common place this shows up because there are so many drivers on one dimmer. Pot light installation sets out how the pairing gets checked at the point of specification, which is where it belongs.
How it runs
One fitting or several, at full output or only dimmed, and whether it follows something switching on. The pattern is most of the answer.
Dimmer and driver checked together first, because that is what it usually is and it costs least to establish.
If the control is not the cause, we work back along the circuit rather than replacing fittings hopefully.
Tested through the whole dimming range rather than just switched on, so the same complaint does not return.
The kind that matters
The pattern to take seriously is different. Lights dip when something large starts, and keep dipping after the appliance has settled. Or several rooms flicker together rather than one fitting. Or it comes and goes with no pattern at all.
Those point at a connection rather than a control: a loose termination somewhere between the panel and the fitting, which heats under load and degrades further each time. That is the same failure described in breaker panel repair, and thermal imaging is the quickest way to find it.
Where several rooms flicker together and lights brighten in one part of the house while dimming in another, that is a different fault again and a partial power outage covers it.
Related work
Common questions
Told us it was a control problem and charged almost nothing. Two others had quoted rewiring.
Recognised from the description that it was not a dimmer. Found a loose neutral.
Matched the dimmer to the drivers properly. Dead steady at every setting now.
Chased it properly rather than telling us to live with it.
From the blog
Next step
Tell us the pattern: one fitting or several, dimmed or full, and whether it follows something switching on.
Control ruled out first · Cheap answers named as cheap · Diagnostic priced up front